If the APOGEE logo banner flashes red and the infrared (IR) strobes repeatedly turn on and off, power-cycle the APOGEE unit and verify that the firmware and APOGEE Intelligent Dashboard (AID) versions are current.
This issue may occur during the calibration alignment phase. The camera images may also appear black, with red X indicators.
The APOGEE logo banner is red or flashes on and off.
The IR strobe or circuit-board indicators flash repeatedly.
The issue occurs during the calibration alignment phase.
Camera images appear black or display red X indicators.
Turn off the APOGEE unit.
Leave the unit powered off for 30–60 seconds.
Turn APOGEE back on.
Open APOGEE Intelligent Dashboard (AID).
Check whether the red banner and flashing IR strobes have stopped.
If the issue occurred during calibration, retry calibration and check the camera images.
If power-cycling does not resolve the issue:
Open AID.
Check the installed APOGEE firmware version.
Check the installed AID version.
Compare the installed versions with the latest available versions on the official TruGolf support page: https://trugolf.com/pages/support
If either version is outdated, follow the published APOGEE update procedure to install the appropriate available update.
Restart APOGEE and check whether the issue is resolved.
For update instructions, see APOGEE: How to Update Firmware and Intelligent Dashboard (AID).
If both firmware and AID are current and the issue persists, the published TruGolf troubleshooting procedure identifies downgrading both firmware and AID as a possible next step.
Important: Downgrading firmware and AID is an advanced procedure. The latest AID version may detect older firmware and force an update back to the current version. Do not attempt to bypass this behavior or install older versions without the correct procedure and guidance.
After completing the applicable steps:
Confirm that the APOGEE logo banner no longer flashes red.
Check that the IR strobes are no longer repeatedly flashing.
Open AID and verify that camera images display normally.
Retry calibration and check whether the alignment phase completes.
Record the APOGEE firmware version, AID version, and the stage at which the red banner and flashing strobes occur. Note whether the camera images are black or display red X indicators.
Collect diagnostic logs using the published APOGEE log-submission procedure so the information is available for further investigation.