APOGEE: How to Update Firmware and Intelligent Dashboard (AID)

APOGEE: How to Update Firmware and Intelligent Dashboard (AID)

APOGEE: How to Update Firmware and Intelligent Dashboard (AID)

To update APOGEE firmware and the APOGEE Intelligent Dashboard (AID), first check the currently installed APOGEE firmware version. The update procedure depends on whether the firmware is .50 or higher or below .50.

Before updating, install the latest version of E6 CONNECT to ensure compatibility with firmware improvements.

E6 CONNECT update: https://e6golf.com/update/e6-connect/

1. Check the Installed Versions

  1. Open APOGEE Intelligent Dashboard (AID).

  2. Locate the current APOGEE firmware version.

  3. If necessary, check the AID version in the lower-right corner of the application. In AID version 2.13, the version appears in the lower-right corner of the Support section if it is not visible on the Dashboard page.

  4. Determine which update procedure applies:

    • Firmware .50 or higher: Follow Process 1.

    • Firmware below .50: Follow Process 2 before updating to the latest release.

2. Process 1: Update APOGEE Firmware .50 or Higher

Step 1: Update Firmware Through AID

  1. Open the existing APOGEE Intelligent Dashboard.

  2. If a firewall-permission prompt appears, ensure all boxes are checked.

  3. Select Tools.

  4. Select the firmware update option and update APOGEE to the latest released firmware.

Step 2: Resolve “Current Version: LOADING” if Displayed

If AID displays “Current Version: LOADING,” use the following published procedure:

  1. Open AID and note the APOGEE device serial number.

  2. Open Windows File Explorer.

  3. Enter the device serial number as a network path using two leading backslashes. For example, if the serial number is G23-0112, enter \\G23-0112.

  4. Press Enter.

  5. When prompted, enter a as the username and a as the password.

  6. Return to AID and retry the firmware update.

Step 3: Update AID

  1. Open the TruGolf support page: https://trugolf.com/pages/support

  2. Download the latest AID version. Do not use version 1.19 for this process.

  3. Install the downloaded version.

  4. If a firewall-permission prompt appears, ensure all boxes are checked.

  5. Return to AID and update APOGEE to the latest released firmware.

If the installed APOGEE firmware is below .50, stop this process and follow Process 2 first.

3. Process 2: Update APOGEE Firmware Below .50

APOGEE units running firmware below .50 require an intermediate update before moving to the latest firmware.

Step 1: Update APOGEE to Firmware .50

  1. Open the existing APOGEE Intelligent Dashboard.

  2. If a firewall-permission prompt appears, ensure all boxes are checked.

  3. Select Tools.

  4. Select the firmware update option and update APOGEE to firmware .50.

Step 2: Resolve “Current Version: LOADING” if Displayed

If AID displays “Current Version: LOADING,” use the following published procedure:

  1. Open AID and note the APOGEE device serial number.

  2. Open Windows File Explorer.

  3. Enter the device serial number as a network path using two leading backslashes. For example, enter \\G23-0112 for device serial number G23-0112.

  4. Press Enter.

  5. When prompted, enter a as the username and a as the password.

  6. Return to AID and retry the firmware update.

Step 3: Install the Required AID Version

  1. Open https://trugolf.com/pages/support

  2. Download AID version 0.0.19, as specified in the published procedure for this legacy firmware path.

  3. Install AID.

  4. If a firewall-permission prompt appears, ensure all boxes are checked.

  5. Update APOGEE to firmware .50.

Step 4: Complete the Update

After APOGEE reaches firmware .50, follow Process 1 to install the latest AID version and update APOGEE to the latest released firmware.

4. Verify the Update

  1. Open AID and verify that the firmware version is displayed.

  2. Confirm that the firmware update completes.

  3. Open E6 CONNECT and verify that APOGEE connects.

  4. Test ball detection and shot registration.

Important Notes

  • Always check the installed firmware version before selecting an update procedure.

  • Firmware below .50 must be upgraded to .50 before proceeding with the standard update process.

  • The published procedure specifies that AID versions higher than 1.25 cannot update APOGEE to firmware .50. Use the designated legacy update path for firmware below .50.

  • If a firmware update does not complete, do not repeatedly install different AID versions at random. Confirm the installed firmware version and follow the applicable process above.