TruTrack 2: Run Optical and Acoustic Diagnostics in E6 CONNECT

TruTrack 2: Run Optical and Acoustic Diagnostics in E6 CONNECT

TruTrack 2: Run Optical and Acoustic Diagnostics in E6 CONNECT

Symptoms

Use this article when TruTrack 2 misses shots, registers shots incorrectly, or needs troubleshooting to determine whether the optical sensors or acoustic microphones are working correctly.

E6 CONNECT includes diagnostic tools that let you test both systems independently.

Step 1: Open TruTrack 2 Diagnostics

  1. Launch E6 CONNECT.

  2. From the main menu, select Settings.

  3. Select Simulator.

  4. Select Tracking System.

  5. Highlight TruTrack 2.

  6. Select the Configure tab.

  7. Select the Diagnostics tab.

Optical diagnostics opens by default.

Step 2: Test the Optical Sensors

The optical sensors detect the club head as it passes over the sensor board.

Check the overhead light

  1. Verify that the overhead light is turned on.

  2. Check that the light beam is focused within the yellow dashed lines displayed in diagnostics.

  3. If the beam is outside the marked area, adjust the overhead light position.

Check sensor board orientation

Verify that the sensor board is installed in the correct direction.

The single row of optical sensors should be closest to the hitting screen.

Check for blocked sensors

Blocked or covered sensors appear red in the diagnostic display.

  1. Inspect the sensor holes for dirt, debris, or artificial grass covering the openings.

  2. If a sensor appears blocked but is not visibly damaged, shine a flashlight directly into it.

  3. Observe whether the sensor changes state.

  4. Carefully trim any overhanging artificial grass.

  5. Vacuum away debris and grass trimmings.

If a sensor clears when illuminated by a flashlight but turns red again when the light is removed, the sensor may not be receiving enough light from the overhead fixture. Adjust the light position and retest.

Test club-head detection

  1. Hold a golf club just above a row of optical sensors.

  2. Move the club slowly across the row.

  3. Verify that the sensors turn red in positions corresponding to the club head.

  4. Repeat the test over the other row.

If the sensors respond to the club head, they are detecting its position.

Step 3: Troubleshoot Optical Sensors That Remain Red

If a sensor remains red even when direct light is applied, inspect the ribbon cable connecting the control box to the optical sensor circuit board.

Before disconnecting cables, power down the system and disconnect its power supply.

  1. Locate the ribbon cable labeled To Sensor Board on the TruTrack 2 control box.

  2. Release the locking clips at the cable connector.

  3. Disconnect the ribbon cable from the control box and sensor board.

  4. Leave it disconnected for approximately one to two minutes.

  5. Inspect the cable for cuts, sharp creases, or damage.

  6. Inspect the connector ports for bent or broken pins.

  7. Reconnect the cable securely and lock the clips back into place.

  8. Restore power and reopen diagnostics.

  9. Retest the affected sensors.

If a sensor remains red despite direct light and a secure cable connection, further hardware troubleshooting may be needed.

Step 4: Troubleshoot Flashing Optical Sensors

Flashing optical sensors may indicate static electricity buildup.

  1. Verify that the ground cable is connected to the TruTrack 2 control box.

  2. Reduce static buildup around the simulator and foot-traffic areas.

  3. If using an anti-static product, follow its instructions and verify that it is suitable for the surfaces being treated.

  4. Keep liquids away from electrical components and connections.

For additional guidance, see How to Control Static in Your Environment with TruGolf.

Step 5: Open Acoustic Diagnostics

To test the acoustic microphones, select Acoustic in the diagnostics interface.

The system uses three microphones:

  • Top center: Near the top center of the simulator frame.

  • Left: Near floor level on the left side of the frame.

  • Right: Near floor level on the right side of the frame.

Each microphone has a corresponding colored indicator bar.

Step 6: Test the Acoustic Microphones

  1. Gently tap the top-center microphone and observe its indicator bar.

  2. Tap the left microphone and observe its indicator bar.

  3. Tap the right microphone and observe its indicator bar.

  4. Verify that each microphone activates its corresponding bar.

If a different bar responds, the microphone cables may be connected to the wrong control-box inputs. Correct the connections and repeat the test.

If a microphone does not respond

Check the following:

  1. Verify that the microphone is connected to its cable.

  2. Verify that the cable is connected to the control box.

  3. Confirm that the microphone is not covered or obstructed.

  4. Swap the microphone with a known-working microphone to isolate the issue.

Interpret the results as follows:

  • The problem follows the microphone: The microphone may be defective.

  • A working microphone also fails in the same position: The cable, connection, or control-box input may be the cause.

  • The microphone works after reconnecting it: The original problem may have been a loose connection.

For Vista series simulators, verify that each microphone sits flush inside its sleeve and faces the hitting screen.

Step 7: Check for Optical Sensors That Never Turn Red

Some optical sensors may remain clear even when covered, which can prevent shots from registering.

  1. Open optical diagnostics.

  2. Cover all optical sensors at the same time.

  3. Verify that every sensor turns red.

  4. Identify any sensor that remains clear.

If one or more sensors remain clear, follow the ribbon-cable troubleshooting procedure in Step 3. Depending on the hardware configuration, reconnecting the sensor board's power may also be necessary.

Verify the Results

After completing the tests:

  1. Confirm that the optical sensors respond to direct light and club-head movement.

  2. Confirm that the acoustic microphones activate their corresponding indicator bars.

  3. Check that all sensor and microphone connections are secure.

  4. Test several golf shots to determine whether registration has improved.

If both diagnostic systems appear to work correctly but shots are still missed, review the guidance in TruTrack 2: Troubleshoot Misread Shots or Shots Not Registering.