Use this article when TruTrack 2 optical sensors appear blocked, remain red in diagnostics, flash intermittently, or fail to detect the club head.
E6 Golf 1.6 includes built-in diagnostics that help identify optical tracking problems. Diagnostics may open automatically when the software detects a problem with the tracking system.
Launch E6 Golf 1.6.
If diagnostics opens automatically, exit Practice or the current round to return to the main menu.
From the main menu, open Options and select Diagnostics.
You can also open diagnostics during a game by selecting the E6 icon and then Diagnostics.
The diagnostics screen defaults to the optical sensor view.
The optical sensors require the overhead light to illuminate the correct area of the sensor board.
Verify that the overhead light is turned on.
Check the light beam against the yellow dashed lines displayed in diagnostics.
Confirm that the beam is focused within the marked area.
If the beam is outside the marked area, adjust the overhead light position.
The TruTrack 2 sensor board must face the correct direction.
The single row of optical sensors should be closest to the hitting screen.
If the sensor board is installed backward, the tracking system may not operate correctly. Verify its orientation before continuing.
Blocked or covered sensors appear red in the diagnostic display.
Inspect the sensor holes for dirt, debris, or artificial grass extending over the openings.
If a sensor appears blocked but is not visibly damaged, shine a flashlight directly into it.
Observe whether the sensor changes state in diagnostics.
Carefully trim any artificial grass covering the sensor holes.
Vacuum away debris and grass trimmings.
If a sensor clears when direct light is applied but becomes red again when the light is removed, it may not be receiving sufficient light from the overhead fixture. Adjust the light position and recheck the sensor.
Hold a golf club just above one row of optical sensors.
Move the club slowly across the row.
Observe the diagnostic display.
Verify that the sensors turn red in positions corresponding to the club head.
Repeat the test over the other row of sensors.
If the sensors change state as the club moves above them, they are responding to the club head.
If the sensors do not respond, continue checking the light placement, sensor openings, and board orientation.
Flashing optical sensors may indicate static electricity buildup.
Verify that the ground cable is connected to the TruTrack 2 control box.
Reduce static buildup around the simulator and foot-traffic areas.
If using an anti-static product, follow its instructions and verify that it is suitable for the surfaces being treated.
Keep liquids away from electrical components and connections.
See How to Control Static in Your Environment with TruGolf for additional guidance.
After making adjustments:
Confirm that the overhead light is on and correctly positioned.
Verify that the sensor holes are clear.
Confirm that the sensor board is oriented correctly.
Repeat the club-head detection test.
Check whether the sensors respond consistently without unexplained flashing.
If the sensors remain blocked despite direct light, or they do not respond when covered by a club head, further hardware troubleshooting may be necessary.
To test the acoustic sensors, select Acoustic at the top of the diagnostics screen.
For instructions on testing the three acoustic microphones and their connections, see TruTrack 2: Acoustic Troubleshooting in E6 Golf 1.6.