Use this article when E6 CONNECT displays “No TruTrack System Found” or cannot detect the TruTrack 2 tracking system.
The most common things to check are the control box power, serial cable connection, and USB-to-serial adapter driver.
Locate the TruTrack 2 control box.
Check the power indicator light. For TruTrack 2 using E6 CONNECT, the indicator should be red.
If the indicator is off, check that the power supply is securely connected.
Verify that the power supply is connected to a working electrical outlet.
If the control box does not power on, resolve the power issue before continuing.
The serial cable carries tracking data from the TruTrack 2 control box to the computer.
Locate the serial cable connecting the control box to the computer.
Verify that the cable is securely connected at both ends.
If your computer uses a USB-to-serial adapter, continue to the next step.
Open Windows Search.
Search for Device Manager and open it.
Expand Ports (COM & LPT).
Look for the USB-to-serial adapter.
If the adapter appears under Ports (COM & LPT), Windows is detecting it.
If it does not appear:
Disconnect the USB adapter from the computer.
Reconnect it.
Check Device Manager again.
Windows may display the adapter under Universal Serial Bus controllers with a yellow warning triangle if the driver is missing or incorrectly installed.
Right-click the affected device.
Select Update driver.
Select Manually Choose or the equivalent manual driver selection option.
Browse to the folder containing the correct USB-to-serial adapter driver.
Complete the driver installation.
If you do not know where the driver is located, refer to the adapter manufacturer's installation instructions.
Confirm that the TruTrack 2 control box power indicator is red.
Verify that the serial cable is securely connected.
Confirm that Windows recognizes the USB-to-serial adapter, if one is used.
Launch E6 CONNECT.
Check whether the “No TruTrack System Found” message has cleared.
If E6 CONNECT still cannot detect TruTrack 2:
Recheck the control box power connection.
Verify the serial cable and USB-to-serial adapter connections.
Confirm that the correct adapter driver is installed.
If the system is detected but shots still do not register, run the tracking diagnostics to check the optical and acoustic sensors.