TruTrack 1: Fix “No TruTrack System Found” in E6 Golf 1.6

TruTrack 1: Fix “No TruTrack System Found” in E6 Golf 1.6

TruTrack 1: Fix “No TruTrack System Found” in E6 Golf 1.6

Symptoms

Use this article when E6 Golf 1.6 displays the error “No TruTrack System Found” or the software cannot detect the TruTrack 1 tracking system.

Possible causes include:

  • The TruTrack system is not receiving power.

  • The serial cable is loose or disconnected.

  • A USB-to-serial adapter driver is missing or incorrectly installed.

  • Windows is not detecting the adapter.

  • The TruTrack processor chip has become loose.

Step 1: Verify TruTrack Power

  1. Locate the TruTrack 1 circuit board.

  2. Verify that the light on the green circuit board is illuminated.

  3. If the light is off, check the system's power connections.

If the system does not appear to have power, resolve the power issue before continuing.

Step 2: Check the Serial Cable

The serial cable carries information from the TruTrack system to the computer.

  1. Locate the serial cable connecting the TruTrack circuit board to the computer.

  2. Verify that the cable is securely connected at both ends.

  3. If a USB-to-serial adapter is being used, continue to the next step to verify its driver.

Step 3: Verify the USB-to-Serial Adapter in Windows

If your installation uses a USB-to-serial adapter, Windows must recognize the adapter and its driver.

  1. Open Windows Search.

  2. Search for Device Manager and open it.

  3. Expand Ports (COM & LPT).

  4. Look for the USB-to-serial adapter.

If the adapter appears under Ports (COM & LPT), Windows is detecting it.

If it does not appear, disconnect and reconnect the adapter to check whether Windows detects it.

If the Adapter Has a Yellow Warning Triangle

Windows may display the adapter under Universal Serial Bus controllers with a yellow triangle if the correct driver is not installed.

  1. Right-click the device.

  2. Select Update driver.

  3. Select Manually Choose.

  4. Browse to the folder containing the adapter's driver.

  5. Complete the driver installation.

If you are using an IOGEAR USB-to-serial adapter, follow the manufacturer's driver installation instructions:

TruGolf: How to Install the IOGEAR USB-to-Serial Adapter Driver

Step 4: Check for a Loose Processor Chip

If TruTrack has power and the serial connection is working but E6 Golf 1.6 still cannot detect the system, a loose processor chip may be the cause.

Safety: Shut down the computer and disconnect power to the TruTrack system before opening the board. Do not work on powered electronics.

The processor inspection procedure is:

  1. Remove the TruTrack board from the floor and turn it over.

  2. Remove the board legs to expose the circuit board.

  3. Use a Phillips screwdriver to remove the back plate.

  4. Locate the black processor chip, approximately 1.5 inches in size.

  5. Check whether the chip is loose in its socket. The original TruGolf procedure instructs pressing down on the chip to reseat it.

  6. Reassemble the board, reconnect it, and return it to its installed position.

Do not force the chip into place or touch exposed circuitry unnecessarily.

For the dedicated procedure, see TruTrack 1: Troubleshoot a Loose Processor Chip.

Verify the Resolution

  1. Confirm that the TruTrack circuit board has power.

  2. Verify that the serial cable is securely connected.

  3. Confirm that Windows recognizes the USB-to-serial adapter, if used.

  4. Launch E6 Golf 1.6.

  5. Verify that the “No TruTrack System Found” message no longer appears.

If the error remains, use the preceding steps to identify which connection or component is not being detected.