Use this procedure when:
MultiSport shots are not registering correctly.
Soccer, Baseball, or Hockey does not track the ball accurately.
The ball is detected inconsistently.
A MultiSport game needs its individual camera settings calibrated.
Important: MultiSport calibration depends on the existing Golf and E6 CONNECT calibration.
Complete the standard TruFlight 2 Golf and E6 CONNECT calibration before proceeding with MultiSport calibration.
Open File Explorer.
Navigate to:
C:\Program Files\E6 Product Launcher\Products\Baseball\Tools
Locate TruFlight2SportsConfig.
Double-click the program to open it.
The utility provides three main options:
Config: Allows you to edit the calibration file.
Default: Restores the default calibration file.
Play: Quickly launches each game to test calibration.
Select Configure next to the game you want to calibrate.
Select Configure next to Soccer.
Select Show Club Camera.
Select Start.
Select the Focus/GS button.
Allow the utility to scan the high and low grayscale values.
Select Accept.
Select Save Changes.
Place a soccer ball in the center of the three dots on the hitting mat.
Select Focus/GS.
Allow the utility to process the ball.
Select Accept.
Select Save Changes.
Place the soccer ball just behind the putting dot so it is outside the live camera view.
Kick the ball toward the screen.
Watch the camera view.
Verify that the ball is marked correctly as it passes through the camera.
Return to the main TruFlight2SportsConfig screen.
Select Configure next to Baseball.
Select Show Club Camera.
Select Start.
Select Focus/GS.
Place the black tee so it just barely covers the putting dot.
Allow the utility to process the grayscale values.
Select Accept.
Select Save Changes.
Place a baseball on top of the tee.
Select Focus/GS.
Allow the utility to process the ball.
Select Accept.
Select Save Changes.
Place the baseball back on the tee.
Hit the ball toward the screen.
Watch the camera view.
Verify that the ball is marked correctly as it passes through the camera.
Select Exit when finished.
Return to the main TruFlight2SportsConfig screen.
Select Configure next to Hockey.
Select Show Club Camera.
Select Start.
Select Focus/GS.
Allow the utility to scan the high and low grayscale values.
Select Accept.
Select Save Changes.
Place the hockey ball in the center of the three dots on the hitting mat.
Select Focus/GS.
Allow the utility to process the ball.
Select Accept.
Select Save Changes.
Place the hockey ball just behind the putting dot so it is outside the live camera view.
Hit the ball toward the screen.
Watch the camera view.
Verify that the ball is marked correctly as it passes through the camera.
Select Exit when finished.
After completing the calibration for the affected games:
Return to the main utility screen.
Use Play to quickly launch a game.
Test ball tracking.
Verify that the ball is detected correctly as it travels toward the screen.
Repeat the appropriate game calibration if the ball is not being detected correctly.
Complete the Golf and E6 CONNECT TruFlight 2 calibration before MultiSport calibration.
Soccer, Baseball, and Hockey each have individual configuration settings.
Always select Save Changes after making calibration adjustments.
Test each game after completing its calibration.