Use this procedure when:
Soccer and other MultiSport games register shots accurately, but QB, Pitching, or Hoops do not.
The ball hits one location on the screen but registers somewhere else in the game.
One MultiSport game is inaccurate while other games appear to work correctly.
QB, Pitching, and Hoops have individual game calibration adjustments.
The MultiSport system must first be calibrated through the TruDepth utility before making adjustments inside individual games.
If you receive a warning that no CFG file exists, complete the TruDepth calibration first.
Launch the affected MultiSport game.
Open the game's Settings menu.
Locate and select Calibration.
The calibration screen will display where the system believes the ball is hitting the screen.
The system displays the estimated impact location as a yellow baseball indicator.
Select RESET before testing for the first time.
This returns the game to the original ISC calibration without additional game-specific adjustments.
Throw a ball at the screen.
Compare the actual location where the ball hits the screen with the yellow indicator showing where the system registered the impact.
If the actual impact and yellow indicator are close: The calibration is working reasonably well. You can optionally use CALIBRATE to fine-tune the game.
If the actual impact and yellow indicator are significantly different: Select RESET and test again.
If the results remain significantly different after resetting: Exit the game and recalibrate the ISC system through the TruDepth utility.
Calibration is generally strongest in the center of the screen and may become less accurate toward the edges.
If the existing calibration is reasonably close but needs adjustment:
Select CALIBRATE.
Throw a ball into the checkerboard area, preferably within the strike zone.
Observe where the yellow indicator shows the system believes the ball hit.
Using a mouse or touchscreen, select the actual location where the physical ball struck the screen.
The calibration will finish after the selection.
Important:
Calibration must be performed inside the checkerboard area.
The program will notify you if you attempt to calibrate outside that area.
You only get one click per calibration attempt.
If you make a mistake, select CALIBRATE again and repeat the process.
You can cancel calibration before completing it. Canceling preserves the previous calibration.
Throw another ball at the screen.
Compare the physical impact location with the registered location.
Repeat the calibration process as needed until the results are acceptable.
Once an adjustment is saved, it remains in place until another calibration is performed or the adjustment is reset.
Select Save/Exit when finished.
The calibration adjustments are saved when you exit the calibration screen.
Always throw or kick the ball firmly.
The ISC camera system does not register slow, lobbed throws as reliably.
Perfect shot registration should not be expected. These games are designed as arcade experiences rather than precision sports simulators.
Calibration adjustments made inside one game do not automatically apply to other games when using the older individual game calibration procedure.