E6 CONNECT — Connect to TruFlight 2

E6 CONNECT — Connect to TruFlight 2

E6 CONNECT — Connect to TruFlight 2

Overview

This article explains how to configure a TruFlight 2 camera tracking system in E6 CONNECT, verify that the cameras are working, and troubleshoot common connection and shot-registration problems.

Symptoms

Use this article if:

  • TruFlight 2 is not available or does not connect in E6 CONNECT.

  • The TruFlight 2 configuration utility cannot detect the cameras.

  • Shots are not registering.

  • Ball or club tracking is inaccurate.

  • The TruFlight 2 configuration utility displays an error after an E6 CONNECT update.

Before You Begin

Confirm that:

  • TruFlight 2 camera hardware is connected to the computer.

  • The required TruFlight 2 Utilities and Drivers are installed.

  • The overhead tracking light is powered on.

  • E6 CONNECT is installed and can launch successfully.

Procedure 1: Install or Check the TruFlight 2 Utilities

  1. Confirm that the TruFlight 2 Utilities and Drivers package is installed.

  2. Open the TruFlight 2 Config Utility from the Windows Start menu or its installed program folder.

  3. Verify that the connected cameras are detected.

  4. Confirm that the camera preview displays an image.

  5. If the preview is black, check that the overhead tracking light is on and that the camera connections are secure.

If the cameras are not detected, continue to the troubleshooting section before configuring E6 CONNECT.

Procedure 2: Select TruFlight 2 in E6 CONNECT

  1. Launch E6 CONNECT.

  2. Open Settings.

  3. Select Simulator.

  4. Select Tracking System.

  5. Choose TruFlight 2.

  6. Select Configure.

  7. Review the available tracking configuration settings and confirm they match the installed TruFlight 2 system.

  8. Select Accept to save the configuration.

  9. Test the system by hitting a shot and confirming that E6 CONNECT registers it.

Procedure 3: Troubleshoot Cameras Not Detected

If the TruFlight 2 Config Utility reports that no cameras are found:

  1. Close E6 CONNECT and the TruFlight 2 Config Utility.

  2. Check that the camera cables are securely connected to the computer.

  3. If the system uses USB cameras, verify that they are connected to the appropriate USB ports for the installation.

  4. Open Windows Device Manager.

  5. Expand the camera or imaging-device category.

  6. Look for a camera device with a warning icon.

  7. If a camera has a warning icon or is not detected, reinstall the appropriate TruFlight 2 camera drivers.

  8. Reopen the TruFlight 2 Config Utility and verify that the cameras are detected.

  9. Relaunch E6 CONNECT and test the system.

If the camera still cannot be detected, contact TruGolf Support.

Procedure 4: Troubleshoot Shots Not Registering

If TruFlight 2 connects but shots are not detected:

  1. Open the TruFlight 2 Config Utility.

  2. Verify that the ball and club cameras are detected and displaying images.

  3. Confirm that the overhead tracking light is on and focused on the designated hitting area.

  4. Check that the ball is positioned within the camera's trigger zone.

  5. Test another shot.

  6. If the problem continues, record which camera or tracking function is failing and contact TruGolf Support.

Procedure 5: Troubleshoot the Config Utility After an E6 CONNECT Update

The TruFlight 2 configuration utility may require an update after E6 CONNECT is updated.

  1. Record the installed E6 CONNECT version.

  2. Open the TruFlight 2 Config Utility.

  3. If the utility displays an error or will not launch following an E6 CONNECT update, check whether a compatible utility update is available.

  4. Use the TruFlight 2 utility update provided by TruGolf.

  5. Install the update and reopen the utility.

  6. Confirm that the cameras are detected before testing E6 CONNECT again.

Do not delete E6 CONNECT program-data folders or replace configuration files as a routine troubleshooting step. Certain TruFlight 2 configurations, including legacy single-ball-camera installations, may depend on specific files and settings.

Resolution

The system is functioning when:

  • The TruFlight 2 Config Utility detects the installed cameras.

  • The camera previews display correctly.

  • TruFlight 2 is selected in E6 CONNECT.

  • Test shots register as expected.

When to Contact TruGolf Support

Contact TruGolf Support if:

  • The cameras are not detected after checking connections and drivers.

  • The TruFlight 2 Config Utility will not launch.

  • Shots continue to fail to register.

  • Camera images or tracking results are abnormal.

  • The system requires a utility update or configuration files that are not available to the customer.

Provide the E6 CONNECT version, TruFlight 2 utility version, camera detection status, any error messages, and the troubleshooting steps already completed.