Connecting the Flightscope X2 Elite Via Ethernet

Connecting the Flightscope X2 Elite Via Ethernet

Symptom:

  1. Need to connect Flightscope X2 to computer through ethernet connection.
To connect the Flightscope X2 Elite you using the Ethernet you will need to follow these steps.
1. Connect the X2 Elite to the Pc with the Ethernet
2. Power on the PC and the Flightscope if you have not already.
3. Launch the FlightScope set up utility located in the C:\Program Files\TruGolf\E6 Golf 1.6
  • Right click on the E6 icon
  • Select open file location
  • Locate the FlightScopeSetupUtility double click to run.

4. You should see the X2 Elite in the primary Sensor box, if so click on the configure tab and skip to step 7
*If you do not see the device listed*


5. Click on the refresh Detect UDP tab.
6. Once the device is seen click on connect (if still not seen please check that the cable is still plugged in and that the FlightScope is still on)
7. Click on the Configure tab
8. Inside the configuration window double check the distance settings and close
9. Launch E6 and go to the practice area to confirm that the FlightScope is connected.

    • Related Articles

    • Connecting a Flightscope Device to E6 Connect

      Symptoms: Needing to connect Flightscope device to E6 Connect Flightscope not connected to E6 Connect Connecting your FlightScope device (such as the Mevo+, X3, or Xi) to E6 Connect is a precise process that requires specific alignment and a ...
    • Connecting a FlightScope device to E6 Golf 2026

      Symptom: Attempting to connect Flightscope device to E6 Golf 2026. Flightscope device not found Solution: Power on the FlightScope. Open the Wi-Fi Settings on the PC you want to connect to. In the network list, find the FlightScope device by its ...
    • How to set Flightscope device to indoor mode in E6 Connect

      Symptoms: E6 Connect crashes when making a shot with Flightscope. Shots with Flightscope are not accurate. Shots with Flightscope do not register. How to set Flightscope to indoor mode. To set your FlightScope to Indoor Mode (or Short Indoor) within ...
    • Connection issues with the Mevo

      Symptom: Flightscope device will not stay connected to E6 Connect. Flightscope disconnects. Unable to get the Mevo + device to connect in the E6 Connect software Make sure the Mevo is updated with the latest firmware Eliminate WiFi interference. ...
    • Flightscope X3 Mode Setup

      Symptoms: Needing to set simulator mode for Flightscope X3. Shots not registering.