If APOGEE displays a red banner and the fans appear red in APOGEE Intelligent Dashboard (AID), allow the unit to finish booting before diagnosing a fan problem. If the fans remain red after one minute, power-cycle the unit and inspect the ventilation openings to determine whether the fans are operating.
A persistent red fan status may indicate hardware failure and could require repair or replacement.
APOGEE displays a red banner.
One or more fans appear red in AID.
APOGEE may not be usable.
The unit may report an unusually high temperature.
Open APOGEE Intelligent Dashboard (AID).
From the main menu, select Status.
Inspect the fan status.
If APOGEE has just been powered on, wait at least one minute for the boot-up cycle to finish.
Check whether the fans still appear red after the unit has finished booting.
A brief red fan status during startup may be normal. A persistent red status after the startup period requires further troubleshooting.
Turn off APOGEE.
Leave the unit powered off for 30–60 seconds.
Turn APOGEE back on.
Wait at least one minute for startup to complete.
Open AID and select Status.
Check whether the fans still appear red.
Inspect the ventilation openings on the sides and back of APOGEE.
Listen for the fans operating.
Where possible, visually check through the vents to determine whether the fans are spinning.
Do not insert objects into the vents or open the unit to access internal components.
Note whether the fans appear to be operating normally or whether one or more appear not to be spinning.
Open AID and select Status.
Review the reported temperature.
Record whether the temperature appears excessively high.
If the fans remain red and the temperature is elevated, stop using the unit until the condition can be evaluated.
If the fan status remains red after power-cycling and the one-minute startup period:
Record the fan status shown in AID.
Record whether the fans can be heard or seen spinning.
Record any unusually high temperature readings.
Collect APOGEE diagnostic logs using the published log-submission procedure.
Keep these observations with the diagnostic logs for further investigation.
A persistent red fan status is indicative of possible hardware failure. The unit may require hardware repair or replacement.