Use these instructions to calibrate your TruGolf APOGEE tracking system using the APOGEE Intelligent Dashboard (AID). Calibration helps the system detect the golf ball and register shots correctly.
Download and install APOGEE Intelligent Dashboard (AID) from the TruGolf Support website if it is not already installed.
Double-click the AID shortcut to launch the application.
From the main menu, select Calibration.
Follow the on-screen instructions to begin calibration.
Place the calibration grid on the hitting area as instructed by AID.
Align the grid square with the screen and position the laser on the designated X.
Follow the on-screen alignment instructions.
Wait until the alignment indicators display green check marks.
Select Next.
APOGEE supports two calibration grid styles:
Older grid: Contains circles without gray and black squares.
Newer grid: Contains circles along with gray and black squares.
Both grid styles can be used for calibration. If your grid has only boxes and is missing the expected circular targets, it may require replacement.
Leave the calibration grid in place.
Allow the automatic grayscale process to complete.
Wait for the green check marks indicating successful calibration.
Select Next.
If automatic grayscale calibration fails:
Check whether the gray and black squares are cut off by the edges of the calibration window.
Adjust the grid slightly so the squares are fully visible.
Restart the automatic grayscale process.
Repeat the adjustment if necessary.
Do not remove the calibration grid until AID instructs you to do so.
If your grid has circles but no gray and black squares, AID will automatically adjust the calibration process.
Follow the on-screen instructions.
When instructed, remove the grid and place a golf ball in the designated area.
Move the ball toward the hitting screen while watching the projected image.
Position the ball where the three bright infrared reflection spots are visible.
Use the + and − controls to adjust the image.
Adjust until the ball's indentation details are clear and the bright spots are not excessively large or oversaturated compared with the reference image.
Continue when the on-screen instructions indicate that this step is complete.
Follow the on-screen instructions for center camera lighting adjustment.
Allow the adjustment to complete.
Wait for the green check marks.
Select Next.
AID will display a shot-testing screen at the end of the calibration process.
Place a golf ball in the hitting area.
Confirm that the Ready indicator displays a green check mark when the ball is detected.
Verify that the left-handed or right-handed setting at the bottom of the screen matches the golfer.
Hit a test shot.
Check that shot data appears on the right side of the screen.
Repeat the test to confirm that the shot data updates consistently.
Save and complete the calibration when shots register correctly.
If shots do not register in AID, test shot registration in E6 CONNECT as well.
If the automatic grayscale step continues to fail, recheck the grid alignment and make sure the squares are not cut off by the edges of the calibration window.
If the laser does not appear during calibration, the issue may involve laser operation or physical alignment. Follow the APOGEE laser troubleshooting procedure.
If the ball is detected but shots do not register, continue with the applicable APOGEE shot-detection troubleshooting procedure.