If E6 CONNECT displays “0 Degree Not Ready,” shots are not registering, or the ball is not being detected, verify that APOGEE is selected as the tracking system in E6 CONNECT and that the device is connected.
This issue can occur during a first-time installation or after an APOGEE device has been replaced.
E6 CONNECT displays the message “0 Degree Not Ready.”
Golf shots are not registering.
The system does not detect the golf ball.
APOGEE has been installed or replaced, but E6 CONNECT is not configured to use it.
Launch E6 CONNECT.
Open Settings.
Select Simulator.
Click Tracking System.
Select APOGEE.
Select Configure.
Select Connect.
Verify that APOGEE connects and appears in the tracking-system list.
Confirm that APOGEE is selected and connected in the tracking-system list.
Return to gameplay or the appropriate test environment.
Place the ball in the hitting area and check whether it is detected.
Hit a test shot and confirm that the shot registers.
If the “0 Degree Not Ready” error persists after APOGEE is selected and connected, do not assume the tracking-system selection is still the cause. Continue troubleshooting the specific connection, calibration, or ball-detection symptoms.